group picture

Accumulator

Order
no.
Article no. Reservoir volume
[cm³]
Gas preload p 0 max.
[bar]
Set gas
preload p0
[bar]
max. permiss. over-pressure
[bar]
Ambient
temp.
[°C]
Weight
[g]
CAD SC
67645 6919S-013 13 250 80 500 -20 - +60 300
67637 6919S-040 40 250 80 400 -20 - +60 650

Design:

- Hydro diaphragm reservoir
- Filling gas = nitrogen, class 4.0
- Pressure fluid: hydraulic oil acc. to DIN 51524 Part 1 and 2; viscosity ISO VG 10 to ISO VG 68 acc. DIN ISO 3448.
- Thread G1/4 A, DIN ISO 228/1 with sealing edge.

Application:

- For short-term compensation of oil losses in stand-by operation;
- to support during switching procedures in hydraulic circuits;
- to compensate for pressure peaks when switching valves;
- for compensation of volume changes of closed circuits in case of temperature changes.

Note:

The reservoirs are manufactured, checked and marked according the technical rules for pressure containers (TRB). Max. permissible operating pressure ratios p2 max : p1 max isothermal = 4:1
Max. permissible operating pressure ratios p2 max : p1 max adiabat = 3:1.