AMF
X
group picture
group picture

Pressure control seat valve

screw-in type,
max. operating pressure 500 bar,
min. operating pressure 40 bar.

Order
no.
Article no. Input pressure
at P max.
[bar]
Adjust. pressure
at A min.
[bar]
Adjust. pressure
at A max.
[bar]
Q
[l/min]
Return line
press. at T
[bar]
DI-1
Seal
Order No.
Weight
[g]
CAD SC
492330 6917E-2-130 500 8 130 6 - 407205 752
326462 6917E-3-130 500 8 130 6 ≤ 20 407205 780
326686 6917E-2-380 500 30 380 12 - 407205 752
326488 6917E-3-380 500 30 380 12 ≤ 20 407205 780

Design:

Leak-oil-free 2-way or 3-way pressure regulating valve as clamp-in valve in seat design, directly actuated. For the 3-way pressure regulating valve, with additional oversteer compensation (integrated pressure-limitation function).
Screw-in thread M24 x 1.5.

Application:

The pressure regulating valve is normally open. With changing, higher input pressure, it maintains the output pressure largely constant. As soon as the set pressure is reached at the consumer, the valve closes and is sealed leak-proof. If the pressure between the valve output and the consumer rises above the set overload value, the excess pressure is reduced over the third connection (T-connection). The valve can be used in front of a directional control valve in the P-channel or behind a directional control valve in the A and/or B-channel.The additional tank connection for the 3-way valve must always be planned.

Features:

For the 3-way valve, the controlled pressure and overload pressure are set simultaneously with an adjusting screw. The overload pressure is always about 10 bar above the regulation pressure. Protection against outside force and puncturing of the valve.

The valve flow regulates P to A. The inlet P is protected against coarse contamination by a filter element with the nominal filter mesh of 100 µm. In the opposite direction at the valve (from A to P), the valve can be flowed through freely. To set and read the pressure, a pressure display device must be installed at the valve outlet. Pressure is adjusted with an adjusting screw. The pressure setting can be sealed.

Note:

Observe mounting instructions.