AMF
X
group picture
group picture

Installation clamping module

Hydraulic opening.
Pneumatic blow-out.
Opening operating pressure: min. 50 bar - max. 60 bar.
Cover and piston hardened.
Repeatability < 0.005 mm.

Order
no.
Size Pull-in/locking force up to
[kN]
Holding force*
[kN]
Blow out Weight
[Kg]
CAD SC
427369 KH10.2 10 25 0,6

Application:

Zero-point clamping system for set-up-time-optimised clamping during cutting and non-cutting machining.

Note:

The installation clamping module KH10.2 is opened with the air-hydraulic pump, order no. 426569, with 5 bar pneumatic input pressure.
The clamping module has high holding, pull-in and locking forces. It is opened hydraulically (1) and mechanically locked through spring force. Subsequent uncoupling of the pressure lines is possible at all times (module is tensioned pressure-free).
The clamping module with blow-out and support control has two connections: 1x hydr. opening (1) / 1x pneum. blow-out and support control (3). (The pneumatic blow-out and support control can optionally be connected.)
* Please observe the installation instructions.

On request:

- Installation diagrams

  • dimensions table
    Order
    no.
    Size dia. D
    dia. DN
    dia. D1 H HA dia. LK
    M T
    427369 KH10.2 112 22 50 30 8 77 M6 22