Installation clamping module “Gonzales”

Hydraulic opening.
Opening operating pressure: min. 50 bar - max. 60 bar.
Cover and piston hardened.
Repeatability < 0.005 mm.

Order
no.
Size Pull-in/locking force up to
[kN]
Holding force*
[kN]
Speedy DockLock Weight
[Kg]
CAD SC
305201 1000 15 25 - 2,3
306043 1000 15 25 - 2,3
305219 2000 25 55 - 3,5

Application:

Zero-point clamping system for set-up-time-optimised clamping during cutting and non-cutting machining.

Note:

Use "Gonzales" modules exclusively with "Gonzales" modules in one clamping. When changing systems, observe the following: Unlike Speedy 1000/2000 and DockLock 1000, "Gonzales"modules require an unclamping pressure of min. 50 bar / max. 60 bar. With recessed installation, observe the cover diameter D 112 mm / 140 mm. The installation clamping module is opened hydraulically (1) and mechanically locked through spring force. Subsequent uncoupling of the pressure lines is possible at all times (module is tensioned pressure-free).
The clamping module has one connection: 1x hydr. opening (1).
* Please observe the installation instructions.

On request:

- Installation diagrams

  • dimensions table
    Order
    no.
    Size dia. D
    dia. DN
    dia. D1 H HA dia. LK
    M T
    305201 1000 112 32 80 36 10 92 8 x M5 26
    306043 1000 112 32 80 36 10 91 10 x M5 26
    305219 2000 140 47 110 36 10 122 8 x M5 26